A Modified Basin Type Solar Still
Keywords:
R.C.C. materials, Glass Sheet
Abstract
To improve the efficiency and reduce the initial cost of solar still a modified unit was designed and tried. The trials showed that besides the top cover, the side walls when fabricated from glass help in increasing its fresh water yield by about fifty per cent. Further a unit with glass sheet costs just half than that of R.C.C. materials.
Published
2014-02-25
How to Cite
Anand, S. (2014). A Modified Basin Type Solar Still. Defence Science Journal, 28(1), 5-6. https://doi.org/10.14429/dsj.28.6523