8 GHz Tunable Gunn Oscillator in WR-137 Waveguide
Keywords:
Coaxial mode, Gunn diode, Waveguide
Abstract
The conventional technique of realising waveguide resonators for Gunn diode oscillators to operate at the band edge of the waveguide fails owing to the excitation of a coaxial mode resonance formed by the post and the side walls of the waveguide. One of the solutions to the problem is to mount the diode in a ridged waveguide resonator. This has been demonstrated by constructing an 8 GHz Gunn oscillator using a single ridge in WR-137 waveguide.The steps in designing the oscillator system are also presented.
Published
2014-01-31
How to Cite
Rakshit, P., Ghosh, G., Saha, P., & Nag, B. (2014). 8 GHz Tunable Gunn Oscillator in WR-137 Waveguide. Defence Science Journal, 33(1), 1-5. https://doi.org/10.14429/dsj.33.6093
Issue
Section
General Papers
Copyright (c) 2016 Defence Science Journal
Where otherwise noted, the Articles on this site are licensed under Creative Commons License: CC Attribution-Noncommercial-No Derivative Works 2.5 India