The sensitivity of flaw detection with x-ray radiographic methods is investigated here qualitatively in case of cast double base and cast composite propellants and for air pockets it is found to be 1.5 and 0.9 percent of the web respectively. General guidelines for the inspection of sustainer charges have also been laid down.