Corrosion Control of Kunifer-5 Seawater Piping Systems of Naval Ships by Cathodic Protection Technique

Authors

  • M. B. Deshmukh Naval Chemical and Metallurgical Laboratory, Bombay
  • P. V. Rodrigues Naval Chemical and Metallurgical Laboratory, Bombay
  • Iqbal Akhtar Naval Chemical and Metallurgical Laboratory, Bombay

DOI:

https://doi.org/10.14429/dsj.32.6191

Keywords:

Corrosion erosion, Kunifer 5, Corrosion

Abstract

The cause of premature corrosion of Kunifer-5(copper alloy containing Ni 5 per cent and Fe 1.35 per cent) pipes used in seawater piping systems on board ships for feeding seawater to various units has been discussed. It has been shown that the Kunifer-5 alloys suffer from heavy corrosion-erosion attack at unavoidable bends and places where local seawater velocity exceeds the specified limit. The field observations as well as laboratory study have indicated that satisfactory protection of the pipes could be achieved by galvanic cathodic protection using aluminium alloy anodes.

Author Biographies

M. B. Deshmukh, Naval Chemical and Metallurgical Laboratory, Bombay

Naval Chemical and Metallurgical Laboratory, Bombay-400 023

P. V. Rodrigues, Naval Chemical and Metallurgical Laboratory, Bombay

Naval Chemical and Metallurgical Laboratory, Bombay-400 023

Iqbal Akhtar, Naval Chemical and Metallurgical Laboratory, Bombay

Naval Chemical and Metallurgical Laboratory, Bombay-400 023

Downloads

Published

2014-02-12

How to Cite

Deshmukh, M. B., Rodrigues, P. V., & Akhtar, I. (2014). Corrosion Control of Kunifer-5 Seawater Piping Systems of Naval Ships by Cathodic Protection Technique. Defence Science Journal, 32(1), 17–26. https://doi.org/10.14429/dsj.32.6191